Search results for "Reference materials"
showing 10 items of 47 documents
A comparative study on sample preparation procedures for supplementary foods by ICP-OES: Green chemistry considerations
2015
An inductively coupled plasma optical emission (ICP-OES) method was developed for the simultaneous determination of major, minor and trace elements in food. Preliminary studies focused on selecting suitable operational conditions in order to provide the highest sensitivity and to maximize the number of analytes to be determined without spectral or matrix interference. Ruthenium and rhenium were evaluated as internal standards and samples were analyzed at different dilution levels. Furthermore, a comparative study was carried out by using three sample digestion methods, microwave-assisted digestion with HNO3/H2O2, dry ashing and dry ashing with Mg(NO3)2/MgO as an ashing aid. Adequate precisi…
Determination of arsenite, arsenate, monomethylarsonic acid and dimethylarsinic acid in cereals by hydride generation atomic fluorescence spectrometry
2007
Abstract A fast, sensitive and simple non-chromatographic analytical method was developed for the speciation analysis of toxic arsenic species in cereal samples, namely rice and wheat semolina. An ultrasound-assisted extraction of the toxic arsenic species was performed with 1 mol L− 1 H3PO4 and 0.1% (m/v) Triton XT-114. After extraction, As(III), As(V), dimethylarsinic acid (DMA) and monomethylarsonic acid (MMA) concentrations were determined by hydride generation atomic fluorescence spectrometry using a series of proportional equations corresponding to four different experimental reduction conditions. The detection limits of the method were 1.3, 0.9, 1.5 and 0.6 ng g− 1 for As(III), As(V)…
Développement de méthodes de référence pour les biomarqueurs du bilan lipidique : application au contrôle qualité en biologie clinique
2013
Reliable measurements in medical biology are essential for early screening and appropriate follow-up of patients. Ensuring metrological traceability of clinical measurements to higher order reference methods or certified reference materials enables to obtain comparable results over time and between different laboratories that could use different methods to quantify the same biomarker.In this study, reference methods were developed and validated for lipid profile biomarkers (total cholesterol, triglycerides, HDL-C, and LDL-C). Their value added in proficiency testing schemes was demonstrated against consensus mean. They were also used to characterize a certified reference material (CRM) that…
Validated fast procedure for trace element determination in basil powder
2011
Abstract An inductively coupled plasma optical emission spectroscopic (ICP-OES) method has been developed and fully validated for trace element determination in basil samples. The method involves the previous sample digestion, under pressure, with a mixture of HNO 3 , HCl and H 2 O 2 inside a microwave oven, 42 elements were studied and 33 elements (Al, As, Ba, Ca, Cr, Co, Cu, Fe, Pb, Li, Mg, Mn, Mo, Ni, K, Se, Na, Sr, Tl, Ti, V, Zn, Sc, Y, La, Ce, Nd, Tb, Ho, Er, Tm, Yb, Lu) were determined quantitatively in basil leaves obtained from Morocco and Spain. The method provided recovery percentages from 89% to 113% for spiked concentrations at mg kg −1 and μg kg −1 . Accurate results were found…
Determination of total mercury in nuts at ultratrace level
2014
Abstract Total mercury, at μg kg−1 level, was determined in different types of nuts (cashew nut, Brazil nuts, almond, pistachio, peanut, walnut) using a direct mercury analyser after previous sample defatting and by cold vapour atomic fluorescence spectrometry. There is not enough sensitivity in the second approach to determine Hg in previously digested samples due to the strong matrix effect. Mercury levels in 25 edible nut samples from Brazil and Spain were found in the range from 0.6 to 2.7 μg kg−1 by using the pyrolysis of sample after the extraction of the nut fat. The accuracy of the proposed method was confirmed by analysing certified reference materials of Coal Fly Ash-NIST SRM 1633…
Mineral Profile of Children’s Fast Food Menu Samples
2017
Abstract Children’s fast food menus, including hamburgers served with french fries, dessert, and a soft drink, were analyzed to obtain the mineral profile of trace elements. The developed analytical methodology involved sample digestion under pressure inside a microwave oven with a mixture of HNO3 and H2O2 and inductively coupled plasma-optical emission spectrometry. The method was validated by carrying out the analysis of certified reference materials (NIST 1570a spinach leaves, NCS ZC73016 chicken, and NIST 1568a rice flour) and using recovery experiments. Repeatability was verified by analyzing replicate samples. Twenty-six elements were studied, 12 of which—aluminum, barium, calcium, co…
Hard cap espresso extraction-stir bar preconcentration of polychlorinated biphenyls in soil and sediments.
2017
Abstract A Nespresso © hard cap espresso machine has been employed for the quantitative extraction of polychlorinated biphenyls (PCBs) from sediments and soils. Sample extraction was performed from five grams of sample in less than 40 s, with 200 mL ethanol 40% (v/v) in water and PCBs were concentrated using stir bar sorptive extraction (SBSE) and determined by thermal desorption-gas chromatography-tandem mass spectrometry (TD-GC-MS-MS). Eleven PCB congeners (28, 52, 77, 80, 81, 101, 118, 138, 153,169, and 180) were determined in soils and sediments with limits of quantification in the 0.03–0.08 ng g −1 range. Extraction efficiency was established by the analysis of soil samples spiked with…
The International Measurement Evaluation Programme (IMEP) IMEP-6: "Trace elements in water"
1998
The sixth round of the International Measurement Evaluation Programme (IMEP) is presented. The programme offers reference values, established by primary methods of measurement, against which participating laboratories can evaluate their performance. The degree of comparability is thus established against the most objective references available at present. In IMEP-6, reference values for total concentrations of 14 trace elements in a synthetic and a natural water were established mainly by isotope dilution mass spectrometry (IDMS). For the majority of the measurands, results traceable to the international system of units (SI) and having expanded uncertainties, U (k=2), of 2% could be establi…
On-line speciation of mercury in fish by cold vapour atomic fluorescence through ultrasound-assisted extraction
2004
A fully mechanized procedure has been developed for the speciation of mercury in fish samples by using cold vapour atomic fluorescence spectrometry (CV-AFS). Sample slurries in an acid mixture in the presence of a surfactant and with traces of K2Cr2O7, were injected into a flow system, sonicated and merged with 1 ml of an oxidant mixture of KBr/KBrO3 heated at 50 °C in a water bath and total Hg determined by CV-AFS. Sonicated sample slurries were also measured, in the absence of KBr/KBrO3, in order to obtain a second series of data which could be employed to establish the concentrations of free Hg(II). Different compositions of the acidic extractant solutions were evaluated by mixing HCl, H…
Determination of mercury at picogram level in natural waters with inductively coupled plasma mass spectrometry by using 3D printed metal scavengers
2019
The determination of ultra-trace concentrations of Hg in natural water samples via preconcentration using 3D printed metal scavenger technique followed by inductively coupled plasma mass spectrometry (ICP-MS) was developed. The determination of Hg in certified reference material ERM-CA615 (groundwater) was performed with high accuracy and precision resulting in recovery of 100 ± 3% and RSD <2.5%, respectively. Selective laser sintering (SLS) 3D printing was used to fabricate the scavengers using a mixture of polyamide-12 powder with thiol-functionalized silica. The preconcentration procedure is based on the adsorption of Hg on the scavenger and followed by elution of the preconcentrated Hg …